・RS-485 Digital communications |
・Analog outputs for EC(conductivity), pH, Temperature |
・Power supply 100~240V |
・The transmission output value converted from the process value is displayed as DC |
on the monitor. |
・pH and EC (electrical conductivity) can be measured with 1 unit. |
・Provided with transmission output to a computer or recorder as standard specifications. |
・Indication with liquid crystal display with backlight that can be easily seen in daytime and at night. |
・pH can be calibrated by one-touch operation. The meter provides further convenience for use. |
・A sunshade cover is included as a standard accessory. |
・The case for measuring apparatus is made of AES resin that has excellent weatherability, and the protection grade of waterproof construction when fitted with the sunshade cover is IP54 or equivalent that enables outdoor use. |
・The EC (electrical conductivity) sensor has employed the 5-electrode method that is resistant to dirt. Stable measurement can be made even at high concentration. |
・The apparatus main body can be fixed by means of a panel/pole attachment tool (the attachment tool is an optional item). |
Applications
・Nutrient solution control in a plant factory. |
・Nutrient solution control in hydroponics (a hydroponic greenhouse). |
・Drainage monitoring in hydroponics (a hydroponic greenhouse). |
Specifications
Type | PCE-12M |
Range of measurement |
EC: 0~10.00mS/cm or 0~20.00mS/cm (measurement range can be switched on the setting screen) |
Display | LCD (with backlight) |
Resolution |
EC:0.01mS/cm pH:0.01pH Temperature: 0.1ºC |
Control output | None |
Transmission output | DC4~20mA(I/O insulation+insulation between outputs) Maximum connection load |
Temperature compensation |
EC: Automatic temperature compensation range 0~50 ℃ 25 ℃ converted conductivity |
Ambient temperature |
0-50℃ |
Error indication | Abnormal measurement value / pH calibration failure / EC electrode in air E display |
Communication | Communication standard RS485 |
Select from 1200/2400/4800/9600/19200 / 38400bps | |
Power supply |
Rated voltage AC100-240V Single phase 50/60Hz Protective fuse 2A |
Dimensions |
138(W)×138(H)×174(D) |
Weight |
About 1 kg |
Optional items |
Flow-through pH electrode S200CY10, Flow-through electrode holder FC75, pole attachment tool, panel attachment tool |
Type | CES-10S |
Construction | Throw-in type |
sample temperature | 0-50℃ |
Material of connection part |
Electrode: titanium Case: PVC |
Lead length | 10m |
Type | S5610R |
Construction | Throw-in type |
sample temperature | 0-50℃ |
Material of connection part |
PVC PP |
Lead length | 10m |
![]() |
|